pid_autotune [2017/07/03 09:36]
Matthew Upp
pid_autotune [2018/01/30 18:35] (current)
Matthew Upp
Line 18: Line 18:
  
 Example: Example:
 +M106 S204 ; turn on hotend fan to 80%
 M303 S210 C15 M303 S210 C15
 +M500 ; save the generated PID values to EEPROM
 </​code>​ </​code>​
  
Line 52: Line 54:
  
 ==== M304 Set PID parameters - Bed ==== ==== M304 Set PID parameters - Bed ====
-Enter the values received after running [[pid_autotune#​m303_run_pid_tuning|M303]] using M301 command+Enter the values received after running [[pid_autotune#​m303_run_pid_tuning|M303]] using M304 command
 <​code>​ <​code>​
 M304 P<Kp value> I<Ki value> D<Kd value> M304 P<Kp value> I<Ki value> D<Kd value>
pid_autotune.1499074572.txt.gz · Last modified: 2017/07/03 09:36 by Matthew Upp